We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Tension-tension tests on turned, electro-chemical machined (ECM) and electro-discharge textured (EDT) specimens made from Ti-45Al-2Nb-2Mn+0.8 vol% TiB2 alloy, showed the turned specimens to have a higher fatigue strength ∼475 MPa. It is likely that this was due to the presence of highly compressive surface residual stresses caused by the turning operation. © 2001 Elsevier Science Ltd.