We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

A Python computer program for calculation of distortion in the wide-band diode bridge track and hold amplifier (THA) is proposed. The computer program calculates the distortion of weekly nonlinear THA based on the KCL and the nonlinear-current method with an improved process. Simulations based on a commercially available 130 nm process technology are performed with the SpectreRF simulator. Comparative SpectreRF simulated results for the diode bridge THA have shown good agreement with those of computer program calculation, whereas the overall computational efficiency has been improved in a special evaluation. © 2013 IEEE.

Original publication

DOI

10.1109/ASQED.2013.6643585

Type

Conference paper

Publication Date

01/01/2013

Pages

188 - 191